SYNOPSIS

tonedebug [options]

DESCRIPTION

The tonedebug utility assists with quickly testing tone detector parameters against the signals they are intended to detect. It has three main modes of operation for testing single continuous or pulsed tones, or for testing a set of tones specified in the environment.

OPTIONS

The following common options apply for all modes:

--card number

Explicitly select the card to test. Default is card 0.

--port number

Explicitly select the port to test. Default is port 0 of the card being tested.

-w wavfile

Specify a wav file to play the tones from. For OpenLine and OpenSwitch cards it should be played to an FXO port with no phone line connected, and the tone detector will process the reflected signal from the hybrid circuit. The OpenPCI cards have almost no echo from this circuit, but an on hook phone connected to an FXS port should produce a detectable echo signal.

-s filename.c

Writes out a C function that can be included in your own code to configure the tone generator with the settings being tested.

Environment options

To run tonedebug using the settings specified with the VPB_TONE environment variables, call it with the -e option. For example:

$ tonedebug -e --port 4 -w my.wav

Will use the enviroment settings to try and detect tones from my.wav played into port 4 of card 0. There are no other options specific to this mode.

Continuous tone options

If passed the -c option, then the tonedebug utility will test parameters suitable for a continuous tone. For example:

$ tonedebug -c 425 100 2000 -w dialtone.wav -t dial

Will try to detect 2 seconds of 425Hz tone from dialtone.wav, played into port 0 of card 0. If it succeeds it will report a dial event. The following additional options may be used in this mode:

-c center-freq bandwidth duration

Specifies the primary tone characteristics, its frequency and bandwidth in Hz. and its minimum duration in milliseconds.

-d center-freq2 bandwidth2

Specifies the second tone of a multi-frequency tone.

-q twist

Specifies the twist of a multi-frequency tone.

-n snr

Specifies the acceptable signal to noise ratio, in dB.

-t dial | busy | ringback

Specifies the name of a predefined tone to replace with the given settings.

Pulsed tone options

The -p options will enable testing for pulsed tones. In addition to the common options and the options for continuous tones, the following options are supported in this mode:

-p center-freq bandwidth on-time

Specifies the primary tone characteristics, its frequency and bandwidth in Hz. and its 'on' time in milliseconds.

-off off-time

The 'off' time of the pulse in milliseconds.

RELATED TO tonedebug…

BUGS

We rely on an echo from the hardware to feed the signal into the tone detector. This should be fixed to feed it in directly at some stage in the future.

AUTHOR

Ron Lee, David Rowe, Voicetronix <[email protected]>

This manual page was written by Ron <[email protected]>, for the Debian project (but may be used by others).