SYNOPSIS

Temperature Voltage and Current.

30 [.]XXXXXXXXXXXX[XX][/[ amphours | current | currentbias | lock.[0-1|ALL] | memory | pages/page.[0-1|ALL] | PIO | sensed | temperature | vbias | vis | volt | volthours |

cc | ce | coc | defaultpmod | defaultswen | dc | de | doc | mstr | ov | ps | pmod | swen | uv |

address | crc8 | id | locator | r_address | r_id | r_locator | type ]]

Thermocouple

30 [.]XXXXXXXXXXXX[XX][/[ temperature | typeX/range_low | typeX/range_high | typeX/temperature ]]

Weather Station

30 [.]XXXXXXXXXXXX[XX][/[ WS603/temperature | WS603/wind_speed | WS603/direction | WS603/volt |

WS603/LED/status | WS603/LED/control.ALL | WS603/LED/model |

WS603/calibrationwind_speed | WS603/calibration/direction |

WS603/light/intensity | WS603/light/threshold

FAMILY CODE

30

SPECIAL PROPERTIES

amphours

read-write, floating point

Accumulated amperage read by current sensor. Units are in Amp-hr (Assumes internal 25mOhm resistor). Derived from volthours / Rinternal.

Formally amphours is the integral of current - currentbias over time.

current

read-only, floating point

Current reading. Units are in Amp (Assumes internal 25 mOhm resistor). Derived from vis / Rinternal.

currentbias

read-write, floating point

Fixed offset applied to each current measurement. Used in the amphours value. Assumes internal 25mOhm resistor. Units are Amp and range from -.08A to .08A.

Derived from vbias / Rinternal.

lock.[0-1|ALL]

read-write, yes-no

Lock either of the two eprom pages to prevent further writes. Apparently setting lock is permanent.

memory

read-write, binary

Access to the full 256 byte memory range. Much of this space is reserved or special use. User space is the page area.

See the DATASHEET for a full memory map.

pages/pages.[0-1|ALL]

read-write, binary Two 16 byte areas of memory for user application. The lock property can prevent further alteration.

NOTE that the page property is different from the common OWFS implementation in that all of memory is not accessible.

PIO

write-only, yes-no

Controls the PIO pin allowing external switching.

Writing "1" turns the PIO pin on (conducting). Writing "0" makes the pin non-conducting. The logical state of the voltage can be read with the sensed property. This will reflect the current voltage at the pin, not the value sent to PIO

Note also that PIO will also be altered by the power-status of the DS2670 See the datasheet for details.

sensed

read-only, yes-no

The logical voltage at the PIO pin. Useful only if the PIO property is set to "0" (non-conducting).

Value will be 0 or 1 depending on the voltage threshold.

temperature

read-only, floating point

Temperature read by the chip at high resolution (~13 bits). Units are selected from the invoking command line. See owfs(1) or owhttpd(1) for choices. Default is Celsius.

Conversion is continuous.

vbias

read-write, floating point

Fixed offset applied to each vis measurement. Used for the volthours value. Units are in Volts.

Range -2.0mV to 2.0mV

vis

read-only, floating point

Current sensor reading (unknown external resistor). Measures the voltage gradient between the Vis pins. Units are in Volts

The vis readings are integrated over time to provide the volthours property.

The current reading is derived from vis assuming the internal 25 mOhm resistor is employed. There is no way to know this through software.

volt

read-only, floating point

Voltage read at the voltage sensor;. This is separate from the vis voltage that is used for current measurement. Units are Volts

Range is between 0 and 4.75V

volthours

read-write, floating point

Integral of vis - vbias over time. Units are in volthours

THERMOCOUPLE

typeX/

directory

Thermocouple circuit using the DS2760 to read the Seebeck voltage and the reference temperature. Since the type interpretation of the values read depends on the type of thermocouple, the correct directory must be chosen. Supported thermocouple types include types B, E, J, K, N, R, S and T.

typeX/range_low typeX/ranges_high

read-only, flaoting point

The lower and upper temperature supported by this thermocouple (at least by the conversion routines). In the globally chosen temperature units.

typeX/temperature

read-only, floating point

Thermocouple temperature. Requires a voltage and temperature conversion. Returned in globally chosen temperature units.

Note: there are two types of temperature measurements possible. The temperature value in the main device directory is the reference temperature read at the chip. The typeX/temperature value is at the thermocouple junction, probably remote from the chip.

WEATHER STATION

WS603

directory

Weather station from AAG electronica that includes temperature, wind speed, wind direction, light sensor and LED lights.

WS603/temperature

read-only, floating-point

Uses the DS2760 temperature sensor. This is equivalent to the temperature value. Again in the specificed temperature scale, default Celsius.

WS603/wind_speed

read_only, floating-point

Readings from the anometer, scaled using the WS603/calibration/wind_speed

WS603/direction

read_only, unsigned integer

Wind direction, using the following table

1

N

2

NNE

3

NE

4

NEE

5

E

6

EES

7

ES

8

ESS

9

S

10

SSW

11

SW

12

SWW

13

W

14

WWN

15

WN

16

WWN

Values are adjusted (internally) by the WS603/calibration/direction property

WS603/volt

read-only, unsigned integer

Voltage value from the WS603 device. Units and significance is unclear.

WS603/calibration/wind_speed

read-write, unsigned integer

Value between 1 and 200 for wind speed scaling. Values on of this range are ignored and the default value of 100 used.

WS603/calibration/direction

read-write, unsigned integer

Adjustment of wind direction. See datasheet.

WS603/light/intensity

read-only, unsigned integer

Uncalibrated value from an internal light sensor. Used for control of LED display (daytime vs nighttime).

WS603/light/threshold

read-only, unsigned integer

Threshold for internal light sensor. Used for control of LED display (daytime vs nighttime).

Value is set as value 4 of the array passed to WS603/LED/control

WS603/LED/status

read-only, unsigned integer

Status of LED lights intensities. See datasheet.

Value is set as values 2 and 3 of the array passed to WS603/LED/control

WS603/LED/model

read-only, unsigned integer

What factors control LED display. See datasheet.

Value is set as value 1 of the array passed to WS603/LED/control.ALL

WS603/LED/model

write-only, unsigned integer array of 4 values

Four integers sent to control LED display. All four values must be sent, comma separated.

0

Light mode

1

Light status

2

Light level

3

Light threshold

OBSCURE PROPERTIES

cc ce coc dc de doc mstr ov pmod swen uv

varies, yes-no

Bit flags corresponding to various battery management functions of the chip. See the DATASHEET for details of the identically named entries.

In general, writing "0" corresponds to a 0 bit value, and non-zero corresponds to a 1 bit value.

defaultpmod defaultswen

read-write, yes-no

Default power-on state for the corresponding properties.

STANDARD PROPERTIES

address

r_address

read-only, ascii

The entire 64-bit unique ID. Given as upper case hexidecimal digits (0-9A-F).

address starts with the family code

r address is the address in reverse order, which is often used in other applications and labeling.

crc8

read-only, ascii

The 8-bit error correction portion. Uses cyclic redundancy check. Computed from the preceding 56 bits of the unique ID number. Given as upper case hexidecimal digits (0-9A-F).

family

read-only, ascii

The 8-bit family code. Unique to each type of device. Given as upper case hexidecimal digits (0-9A-F).

id

r_id

read-only, ascii

The 48-bit middle portion of the unique ID number. Does not include the family code or CRC. Given as upper case hexidecimal digits (0-9A-F).

r id is the id in reverse order, which is often used in other applications and labeling.

locator

r_locator

read-only, ascii

Uses an extension of the 1-wire design from iButtonLink company that associated 1-wire physical connections with a unique 1-wire code. If the connection is behind a Link Locator the locator will show a unique 8-byte number (16 character hexidecimal) starting with family code FE.

If no Link Locator is between the device and the master, the locator field will be all FF.

r locator is the locator in reverse order.

present (DEPRECATED)

read-only, yes-no

Is the device currently present on the 1-wire bus?

type

read-only, ascii

Part name assigned by Dallas Semi. E.g. DS2401 Alternative packaging (iButton vs chip) will not be distiguished.

ALARMS

None.

DESCRIPTION

1-Wire

1-wire is a wiring protocol and series of devices designed and manufactured by Dallas Semiconductor, Inc. The bus is a low-power low-speed low-connector scheme where the data line can also provide power.

Each device is uniquely and unalterably numbered during manufacture. There are a wide variety of devices, including memory, sensors (humidity, temperature, voltage, contact, current), switches, timers and data loggers. More complex devices (like thermocouple sensors) can be built with these basic devices. There are also 1-wire devices that have encryption included.

The 1-wire scheme uses a single bus master and multiple slaves on the same wire. The bus master initiates all communication. The slaves can be individually discovered and addressed using their unique ID.

Bus masters come in a variety of configurations including serial, parallel, i2c, network or USB adapters.

OWFS design

OWFS is a suite of programs that designed to make the 1-wire bus and its devices easily accessible. The underlying priciple is to create a virtual filesystem, with the unique ID being the directory, and the individual properties of the device are represented as simple files that can be read and written.

Details of the individual slave or master design are hidden behind a consistent interface. The goal is to provide an easy set of tools for a software designer to create monitoring or control applications. There are some performance enhancements in the implementation, including data caching, parallel access to bus masters, and aggregation of device communication. Still the fundemental goal has been ease of use, flexibility and correctness rather than speed.

DS2760 DS2761 DS2762

The DS2760 (3) is a class of battery charging controllers. There are minor hardware difference between the DS2760, DS2761 and DS2762 battery chip, but they are indistiguishable to the software.

A number of interesting devices can be built with the DS276x including thermocouples. Support for thermocouples in built into the software, using the embedded thermister as the cold junction temperature.

For an explanation of the differences between the DS276x variants, see Dallas Application Note 221.

ADDRESSING

All 1-wire devices are factory assigned a unique 64-bit address. This address is of the form:

Family Code

8 bits

Address

48 bits

CRC

8 bits

Addressing under OWFS is in hexidecimal, of form:

  • 01.123456789ABC

where 01 is an example 8-bit family code, and 12345678ABC is an example 48 bit address.

The dot is optional, and the CRC code can included. If included, it must be correct.

DATASHEET

http://pdfserv.maxim-ic.com/en/ds/DS2760.pdf

http://pdfserv.maxim-ic.com/en/an/app221.pdf

http://www.aag.com.mx/aagusa/contents/en-us/Description%20of%20WSV3%20Interface%20(1-wire).pdf

RELATED TO DS2761…

Programs

owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread (1) owwrite (1) owpresent (1) owtap (1)

Configuration and testing

owfs (5) owtap (1) owmon (1)

Language bindings

owtcl (3) owperl (3) owcapi (3)

Clocks

DS1427 (3) DS1904(3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417 (3)

ID

DS2401 (3) DS2411 (3) DS1990A (3)

Memory

DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3) DS1995 (3) DS1996 (3) DS2430A (3) DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3) DS28E04 (3) DS28EC20 (3)

Switches

DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3)

Temperature

DS1822 (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921 (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3) EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826 (3)

Humidity

DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)

Voltage

DS2450 (3)

Resistance

DS2890 (3)

Multifunction (current, voltage, temperature)

DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760 (3) DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3)

Counter

DS2423 (3)

LCD Screen

LCD (3) DS2408 (3)

Crypto

DS1977 (3)

Pressure

DS2406 (3) TAI8570 EDS0066 (3) EDS0068 (3)