w1retap1
Data logger for 1-wire weather sensors
Usage
w1retap [OPTIONS]
Overview
The w1retap package reads weather sensors on a 1-Wire bus and data logs the retrieved data to the configured databases or files. It supports a number of different 1-Wire host bus adapters and 1-Wire sensors designed by Dallas Semiconductor Corp (now Maxim Integrated) and compatible sensors including those from AAG Electrónica and other hobby sensors.
Options
-
-h, --help -
Show help options
-
-w, --wait -
At startup, wait until next interval
-
-1, --once-only -
Read once and exit
-
-R, --release-interface -
Release the 1Wire interface between reads
-
-d, --daemonise -
Daemonise (background) application
-
-T, --no-tmp-log -
Disables /var/lib/w1retap/.w1retap.dat logging
-
-l, --tmp-log-name=FILE -
Names logging file (/var/lib/w1retap/.w1retap.dat)
-
-i, --interface=DEVICE -
Interface device, the DEVICE can be serial DS2480 adaptor or a USB DS2490-1 adaptor. Use the serial device node (eg /dev/ttyS0 or /dev/ttyUSB0) for serial or use DS2490-1 to use libusb for a USB adaptor.
-
-t, --cycle-time=SECS -
Time (secs) between device readings
-
-N, --dont-read -
Don’t read sensors (for debugging)
-
-v, --verbose -
Verbose messages
-
-o, --vane-offset=VAL -
Value for N for weather vane (0-15)
-
-V, --version -
Display version number (and exit)
-
-s, --simulate -
Simulate readings (for testing, not yet implemented)
-
-u, --use-utc -
Store dates as UTC (vice localtime)
-
-r, --report-log=FILE -
Report log file
Examples
• $ w1retap -l -i /dev/ttyUSBS0 -v
Signals
The w1retap daemon accepts three signals. SIGUSR1 causes it to read all the sensors immediately. SIGUSR2 causes it to print the current configuration. SIGHUP causes it to re-read the configuration.
Exit status
0
Returns 0 on success or failure
Resources
• /usr/share/doc/w1retap-doc/w1retap.odt
• http://www.zen35309.zen.co.uk/wx/tech.html
Releases