vendstat8
Query infiniband vendor specific functions
Usage
vendstat {[options]
<lid | guid>}
Overview
vendstat uses vendor specific MADs to access beyond the IB spec vendor specific functionality. Currently, there is support for Mellanox InfiniSwitch-III (IS3) and InfiniSwitch-IV (IS4).
Options
-
-N -
show IS3 or IS4 general information.
-
-w -
show IS3 port xmit wait counters.
-
-i -
show IS4 counter group info.
-
-c <num,num> -
configure IS4 counter groups.
Configure IS4 counter groups 0 and 1. Such configuration is not persistent across IS4 reboot. First number is for counter group 0 and second is for counter group 1.
Group 0 counter config values:
0 - PortXmitDataSL0-7
1 - PortXmitDataSL8-15
2 - PortRcvDataSL0-7
Group 1 counter config values:
1 - PortXmitDataSL8-15 2 - PortRcvDataSL0-7 8 - PortRcvDataSL8-15
-
-R, --Read <addr,mask> -
Read configuration space record at addr
-
-W, --Write <addr,val,mask> -
Write configuration space record at addr
Addressing Flags
-G, --Guid The address specified is a Port GUID
-L, --Lid The address specified is a LID
-s, --sm_port <smlid> use 'smlid' as the target lid for SA queries.
Port Selection flags
-C, --Ca <ca_name> use the specified ca_name.
-P, --Port <ca_port> use the specified ca_port.
-
-Y, --pkey-idx <idx> -
P_Key table index (0-65535, default 0) used for the outgoing SA/GMP MADs. SMP (SMI directed-route/LID-routed) MADs always use P_Key index 0.
Local port Selection
Multiple port/Multiple CA support: when no IB device or port is specified (see the "local umad parameters" below), the libibumad library selects the port to use by the following criteria:
1.
|
the first port that is ACTIVE. |
|---|---|
2.
|
if not found, the first port that is UP (physical link up). |
If a port and/or CA name is specified, the libibumad library attempts to fulfill the user request, and will fail if it is not possible.
For example:
ibaddr # use the first port (criteria #1 above) ibaddr -C mthca1 # pick the best port from "mthca1" only. ibaddr -P 2 # use the second (active/up) port from the first available IB device. ibaddr -C mthca0 -P 2 # use the specified port only.
Debugging flags
-
-d -
raise the IB debugging level. May be used several times (-ddd or -d -d -d).
-
-e -
show send and receive errors (timeouts and others)
-h, --help show the usage message
-
-v, --verbose -
increase the application verbosity level. May be used several times (-vv or -v -v -v)
-V, --version show the version info.
Configuration flags
-t, --timeout <timeout_ms> override the default timeout for the solicited mads.
--config, -z <config_file> Specify alternate config file.
Default: /etc/infiniband-diags/ibdiag.conf
Files
Config file
/etc/infiniband-diags/ibdiag.conf
A global config file is provided to set some of the common options for all tools. See supplied config file for details.
Examples
vendstat -N 6 # read IS3 or IS4 general information vendstat -w 6 # read IS3 port xmit wait counters vendstat -i 6 12 # read IS4 port 12 counter group info vendstat -c 0,1 6 12 # configure IS4 port 12 counter groups for PortXmitDataSL vendstat -c 2,8 6 12 # configure IS4 port 12 counter groups for PortRcvDataSL
Releases
9 releases since Debian 6.0 (Squeeze); the text changed 6 times.
--Read since Debian 10 (Buster);
--Write since Debian 10 (Buster);
--pkey-idx since Arch Linux 2026-11-01;
--verbose since Debian 10 (Buster);
-N since Debian 10 (Buster);
-R since Debian 10 (Buster);
-W since Debian 10 (Buster);
-Y since Arch Linux 2026-11-01;
-c since Debian 10 (Buster);
-d since Debian 10 (Buster);
-e since Debian 10 (Buster);
-i since Debian 10 (Buster);
-v since Debian 10 (Buster);
-w since Debian 10 (Buster).