rhino(8)

rhino8

Driver for brazilian microsol rhino ups equipment

Usage

rhino -h

rhino -a UPS_NAME [OPTIONS]

Supported hardware

This driver has been tested with:

• Rhino 6000 VA

• Rhino 7500 VA

• Rhino 10000 VA

• Rhino 20000 VA

All Rhino models are sinusoidal on-line.

Extra arguments

This driver support the following extra optional settings in ups.conf(5):

battext=n

Default = 0, no extra battery, where n = Ampere*hour.

Commands

load.on

Turn on the load immediately.

load.off

Turn off the load immediately.

bypass.start

Put the UPS in bypass mode.

bypass.stop

Put the UPS out of bypass mode.

shutdown.stayoff

Shut down in 3 minutes and do not return.

Releases

10 releases since Debian 5.0 (Lenny); the text changed 6 times.

  1. 5.0–6.0
  2. 7
  3. 8
  4. 9–11
  5. 12
  6. 13
  7. Arch

Author

Silvino B. Magalhães <[email protected]>