pulseview1
Qt-based la/scope/mso gui for sigrok
Usage
pulseview [OPTIONS]
[FILE]
Overview
PulseView is a cross-platform Qt-based GUI for the sigrok software suite for test and measurement equipment such as logic analyzers, oscilloscopes, MSOs, and more.
Options
PulseView has very few command line options, as most configuration elements are available from the GUI itself.
If the optional FILE argument is supplied, PulseView tries to open the specified file. It has to be in the "libsigrok session" format (.sr) unless -I is used to specify the input file format.
-
-l, --loglevel -
Set the libsigrok and libsigrokdecode loglevel. At the moment PulseView doesn't support setting the two loglevels independently. The higher the number, the more debug output will be printed. Valid loglevels are:
0None
1Error
2Warnings
3Informational
4Debug
5Spew
-
-h, -?, --help -
Show a help text and exit.
-
-V, --version -
Show version information and exit.
-
-d, --driver <drivername> -
Specify the capture device to connect to. If the
--driveroption is not supplied, PulseView attempts to re-connect to the most recently used device, or auto-detect available devices.
-
-D, --dont-scan -
Usually PulseView automatically scans all drivers to find suitable devices during program startup. This option disables the auto-scan. Users can either specify the
--driveroption to pick a device at startup, or interactively scan for devices after PulseView has finished starting up.
-
-i, --input-file <filename> -
Load input from a file. If the
--input-formatoption is not supplied, PulseView attempts to load the file as a sigrok session file.
-
-I, --input-format <format> -
Specifies the format of the input file to be loaded.
-
-s, --settings <filename> -
Load PulseView session setup to use with the input file. The setup file must be in the "PulseView session setup" format (.pvs).
-
-c, --clean -
Prevents the previously used sessions to be restored from settings storage. This is useful if you want only a single session with the file given on the command line instead of restoring all previously used sessions as well.
Keyboard shortcuts
f-
Zoom-to-fit.
s-
Enable / disable sticky scrolling. When enabled, the right edge of the screen always shows the most recently captured data.
- .
-
Show / hide sampling points.
g-
Show / hide analog minor grid (in addition to the vdiv grid).
c-
Show / hide cursors.
d-
Show / hide protocol decoder selector.
b-
Toggle between coloured trace backgrounds and alternating light/dark gray trace backgrounds.
- SPACE
-
Start / stop an acquisition.
- Left/right arrow keys
-
Scroll left/right.
- +/-
-
Zoom in/out.
- Up/down arrow keys
-
Zoom in/out.
Home/End-
Jump to the start/end of the sample data.
1/2-
Attach left/right side of the cursors to the mouse.
CTRL+o-
Open file.
CTRL+s-
Save as...
CTRL+r-
Save selected range as...
CTRL+g-
Group all currently selected traces into a trace group.
CTRL+u-
Ungroup the traces in the currently selected trace group.
- CTRL+up/down arrow keys
-
Scroll down/up.
CTRL+q-
Quit, i.e. shutdown PulseView (closing all session tabs).
CTRL+w-
Close the current session tab.
Exit status
PulseView exits with 0 on success, 1 on most failures.
Releases
6 releases since Debian 8 (Jessie); the text changed 2 times.
--clean since Debian 10 (Buster);
--dont-scan since Debian 10 (Buster);
--driver since Debian 10 (Buster);
--input-file since Debian 10 (Buster);
--input-format since Debian 10 (Buster);
--settings since Debian 11 (Bullseye);
-D since Debian 10 (Buster);
-I since Debian 10 (Buster);
-c since Debian 10 (Buster);
-d since Debian 10 (Buster);
-i since Debian 10 (Buster);
-s since Debian 11 (Bullseye).