ovn-controller8
Open virtual network local controller
Usage
ovn-controller [options]
[ovs-database]
Overview
ovn-controller is the local controller daemon for OVN, the Open Virtual Network. It connects up to the OVN Southbound database (see ovn-sb(5)) over the OVSDB protocol, and down to the Open vSwitch database (see ovs-vswitchd.conf.db(5)) over the OVSDB protocol and to ovs-vswitchd(8) via OpenFlow. Each hypervisor and software gateway in an OVN deployment runs its own independent copy of ovn-controller; thus, ovn-controller’s downward connections are machine-local and do not run over a physical network.
Acl logging
ACL log messages are logged through ovn-controller’s logging mechanism. ACL log entries have the module acl_log at log level info. Configuring logging is described below in the Logging Options section.
Options
Daemon Options
-
--pidfile[=pidfile] -
Causes a file (by default, program
.pid) to be created indicating the PID of the running process. If the pidfile argument is not specified, or if it does not begin with/, then it is created in .
-
If
--pidfileis not specified, no pidfile is created.
-
--overwrite-pidfile -
By default, when
--pidfileis specified and the specified pidfile already exists and is locked by a running process, the daemon refuses to start. Specify--overwrite-pidfileto cause it to instead overwrite the pidfile.
-
When
--pidfileis not specified, this option has no effect.
-
--detach -
Runs this program as a background process. The process forks, and in the child it starts a new session, closes the standard file descriptors (which has the side effect of disabling logging to the console), and changes its current directory to the root (unless
--no-chdiris specified). After the child completes its initialization, the parent exits.
-
--monitor -
Creates an additional process to monitor this program. If it dies due to a signal that indicates a programming error (SIGABRT, SIGALRM, SIGBUS, SIGFPE, SIGILL, SIGPIPE, SIGSEGV, SIGXCPU, or SIGXFSZ) then the monitor process starts a new copy of it. If the daemon dies or exits for another reason, the monitor process exits.
-
This option is normally used with
--detach, but it also functions without it.
-
--no-chdir -
By default, when
--detachis specified, the daemon changes its current working directory to the root directory after it detaches. Otherwise, invoking the daemon from a carelessly chosen directory would prevent the administrator from unmounting the file system that holds that directory.
-
Specifying
--no-chdirsuppresses this behavior, preventing the daemon from changing its current working directory. This may be useful for collecting core files, since it is common behavior to write core dumps into the current working directory and the root directory is not a good directory to use.
-
This option has no effect when
--detachis not specified.
-
--no-self-confinement -
By default this daemon will try to self-confine itself to work with files under well-known directories determined at build time. It is better to stick with this default behavior and not to use this flag unless some other Access Control is used to confine daemon. Note that in contrast to other access control implementations that are typically enforced from kernel-space (e.g. DAC or MAC), self-confinement is imposed from the user-space daemon itself and hence should not be considered as a full confinement strategy, but instead should be viewed as an additional layer of security.
-
--user=user:group -
Causes this program to run as a different user specified in user:group, thus dropping most of the root privileges. Short forms user and :group are also allowed, with current user or group assumed, respectively. Only daemons started by the root user accepts this argument.
-
On Linux, daemons will be granted
CAP_IPC_LOCKandCAP_NET_BIND_SERVICESbefore dropping root privileges. Daemons that interact with a datapath, such asovs-vswitchd, will be granted three additional capabilities, namelyCAP_NET_ADMIN,CAP_NET_BROADCASTandCAP_NET_RAW. The capability change will apply even if the new user is root.
-
On Windows, this option is not currently supported. For security reasons, specifying this option will cause the daemon process not to start.
Logging Options
-
-v[spec]
-
--verbose=[spec] -
Sets logging levels. Without any spec, sets the log level for every module and destination to
dbg. Otherwise, spec is a list of words separated by spaces or commas or colons, up to one from each category below:- •
-
A valid module name, as displayed by the
vlog/listcommand on ovs-appctl(8), limits the log level change to the specified module.
- •
-
syslog,console, orfile, to limit the log level change to only to the system log, to the console, or to a file, respectively. (If--detachis specified, the daemon closes its standard file descriptors, so logging to the console will have no effect.)
-
On Windows platform,
syslogis accepted as a word and is only useful along with the--syslog-targetoption (the word has no effect otherwise).
- •
-
off,emer,err,warn,info, ordbg, to control the log level. Messages of the given severity or higher will be logged, and messages of lower severity will be filtered out.offfilters out all messages. See ovs-appctl(8) for a definition of each log level.
-
Case is not significant within spec.
-
Regardless of the log levels set for
file, logging to a file will not take place unless--log-fileis also specified (see below).
-
For compatibility with older versions of OVS,
anyis accepted as a word but has no effect.
-
-v
-
--verbose -
Sets the maximum logging verbosity level, equivalent to
--verbose=dbg.
-vPATTERN:destination:pattern
-
--verbose=PATTERN:destination:pattern -
Sets the log pattern for destination to pattern. Refer to ovs-appctl(8) for a description of the valid syntax for pattern.
-vFACILITY:facility
-
--verbose=FACILITY:facility -
Sets the RFC5424 facility of the log message. facility can be one of
kern,user,mail,daemon,auth,syslog,lpr,news,uucp,clock,ftp,ntp,audit,alert,clock2,local0,local1,local2,local3,local4,local5,local6orlocal7. If this option is not specified,daemonis used as the default for the local system syslog andlocal0is used while sending a message to the target provided via the--syslog-targetoption.
-
--log-file[=file] -
Enables logging to a file. If file is specified, then it is used as the exact name for the log file. The default log file name used if file is omitted is
/var/log/ovn/program.log.
-
--syslog-target=host:port -
Send syslog messages to UDP port on host, in addition to the system syslog. The host must be a numerical IP address, not a hostname.
-
--syslog-method=method -
Specify method as how syslog messages should be sent to syslog daemon. The following forms are supported:
- •
-
libc, to use the libcsyslog()function. Downside of using this options is that libc adds fixed prefix to every message before it is actually sent to the syslog daemon over/dev/logUNIX domain socket.
- •
-
unix:file, to use a UNIX domain socket directly. It is possible to specify arbitrary message format with this option. However, rsyslogd 8.9 and older versions use hard coded parser function anyway that limits UNIX domain socket use. If you want to use arbitrary message format with olderrsyslogdversions, then use UDP socket to localhost IP address instead.
- •
-
udp:ip:port, to use a UDP socket. With this method it is possible to use arbitrary message format also with olderrsyslogd. When sending syslog messages over UDP socket extra precaution needs to be taken into account, for example, syslog daemon needs to be configured to listen on the specified UDP port, accidental iptables rules could be interfering with local syslog traffic and there are some security considerations that apply to UDP sockets, but do not apply to UNIX domain sockets.
- •
-
null, to discard all messages logged to syslog.
-
The default is taken from the
OVS_SYSLOG_METHODenvironment variable; if it is unset, the default islibc.
PKI Options
PKI configuration is required in order to use SSL/TLS for the connections to the Northbound and Southbound databases.
-
-p privkey.pem
-
--private-key=privkey.pem -
Specifies a PEM file containing the private key used as identity for outgoing SSL/TLS connections.
-
-c cert.pem
-
--certificate=cert.pem -
Specifies a PEM file containing a certificate that certifies the private key specified on
-por--private-keyto be trustworthy. The certificate must be signed by the certificate authority (CA) that the peer in SSL/TLS connections will use to verify it.
-
-C cacert.pem
-
--ca-cert=cacert.pem -
Specifies a PEM file containing the CA certificate for verifying certificates presented to this program by SSL/TLS peers. (This may be the same certificate that SSL/TLS peers use to verify the certificate specified on
-cor--certificate, or it may be a different one, depending on the PKI design in use.)
-
-C none
-
--ca-cert=none -
Disables verification of certificates presented by SSL/TLS peers. This introduces a security risk, because it means that certificates cannot be verified to be those of known trusted hosts.
-
--bootstrap-ca-cert=cacert.pem -
When cacert.pem exists, this option has the same effect as
-Cor--ca-cert. If it does not exist, then the executable will attempt to obtain the CA certificate from the SSL/TLS peer on its first SSL/TLS connection and save it to the named PEM file. If it is successful, it will immediately drop the connection and reconnect, and from then on all SSL/TLS connections must be authenticated by a certificate signed by the CA certificate thus obtained.
-
This option exposes the SSL/TLS connection to a man-in-the-middle attack obtaining the initial CA certificate, but it may be useful for bootstrapping.
-
This option is only useful if the SSL/TLS peer sends its CA certificate as part of the SSL/TLS certificate chain. SSL/TLS protocols do not require the server to send the CA certificate.
-
This option is mutually exclusive with
-Cand--ca-cert.
-
--peer-ca-cert=peer-cacert.pem -
Specifies a PEM file that contains one or more additional certificates to send to SSL/TLS peers. peer-cacert.pem should be the CA certificate used to sign the program’s own certificate, that is, the certificate specified on
-cor--certificate. If the program’s certificate is self-signed, then--certificateand--peer-ca-certshould specify the same file.
-
This option is not useful in normal operation, because the SSL/TLS peer must already have the CA certificate for the peer to have any confidence in the program’s identity. However, this offers a way for a new installation to bootstrap the CA certificate on its first SSL/TLS connection.
Other Options
-
--unixctl=socket -
Sets the name of the control socket on which program listens for runtime management commands (see RUNTIME MANAGEMENT COMMANDS, below). If socket does not begin with
/, it is interpreted as relative to . If--unixctlis not used at all, the default socket is/program.pid.ctl, where pid is program’s process ID.
-
On Windows a local named pipe is used to listen for runtime management commands. A file is created in the absolute path as pointed by socket or if
--unixctlis not used at all, a file is created as program in the configured OVS_RUNDIR directory. The file exists just to mimic the behavior of a Unix domain socket.
-
Specifying
nonefor socket disables the control socket feature.
-
-h
-
--help -
Prints a brief help message to the console.
-
-V
-
--version -
Prints version information to the console.
Configuration
ovn-controller retrieves most of its configuration information from the local Open vSwitch’s ovsdb-server instance. The default location is db.sock in the local Open vSwitch’s "run" directory. It may be overridden by specifying the ovs-database argument as an OVSDB active or passive connection method, as described in ovsdb(7).
ovn-controller assumes it gets configuration information from the following keys in the Open_vSwitch table of the local OVS instance:
external_ids:system-id-
The chassis name to use in the Chassis table. Changing the
system-idwhileovn-controlleris running is not directly supported. Users have two options: either first gracefully stopovn-controlleror manually delete the staleChassisandChassis_Privaterecords after changing thesystem-id. Note that the chassis name can also be provided via thesystem-id-overridefile in the local OVN "etc" directory or via the-ncommand-line option. The following precedence is used: first, the command-line option is read; if not present, thesystem-id-overridefile is read; if not present, then the name configured in the database is used.
external_ids:hostname-
The hostname to use in the Chassis table.
external_ids:ovn-bridge-
The integration bridge to which logical ports are attached. The default is
br-int. If this bridge does not exist when ovn-controller starts, it will be created automatically with the default configuration suggested in ovn-architecture(7). When more than one controllers are running on the same host,external_ids:ovn-bridge-CHASSIS_NAMEshould be set for each of them, pointing to a unique bridge. This is required to avoid controllers stepping on each others’ feet.
external_ids:ovn-bridge-datapath-type-
This configuration is optional. If set, then the datapath type of the integration bridge will be set to the configured value. If this option is not set, then
ovn-controllerwill not modify the existingdatapath-typeof the integration bridge.
external_ids:ovn-remote-
The OVN database that this system should connect to for its configuration, in one of the same forms documented above for the ovs-database.
external_ids:ovn-monitor-all-
A boolean value that tells if
ovn-controllershould monitor all records of tables in theOVN_Southbound. If this option is set tofalse, ovn-controller will conditionally monitor only the records that are needed for the local chassis.
-
It is more efficient to set it to
truein use cases where the chassis would anyway need to monitor most of the records in theOVN_Southbounddatabase, which would save the overhead of conditions processing, especially for server side. Typically, set it totruefor environments where all workloads need to be reachable from each other.
-
NOTE: for efficiency and scalability in common scenarios
ovn-controllerunconditionally monitors all sub-ports (ports withparent_portset) regardless of theovn-monitor-allvalue.
-
Default value is false.
external_ids:ovn-remote-probe-interval-
The inactivity probe interval of the connection to the OVN database, in milliseconds. If the value is zero, it disables the connection keepalive feature.
-
If the value is nonzero, then it will be forced to a value of at least 1000 ms.
external_ids:ovn-encap-type-
The encapsulation type that a chassis should use to connect to this node. Multiple encapsulation types may be specified with a comma-separated list. Each listed encapsulation type will be paired with
ovn-encap-ip.
-
Supported tunnel types for connecting hypervisors and gateways are
geneve,vxlan, andstt.
-
stttunnel type is deprecated.
-
Due to the limited amount of metadata in
vxlan, the capabilities and performance of connected gateways and hypervisors will be reduced versus other tunnel formats.
external_ids:ovn-encap-ip-
The IP address that a chassis should use to connect to this node using encapsulation types specified by
external_ids:ovn-encap-type. Multiple encapsulation IPs may be specified with a comma-separated list.
-
In scenarios where multiple encapsulation IPs are present, distinct tunnels are established for each remote chassis. These tunnels are differentiated by setting unique
options:local_ipandoptions:remote_ipvalues in the tunnel interface. When transmitting a packet to a remote chassis, the selection of local_ip is guided by theInterface:external_ids:encap-ipfrom the local OVSDB, corresponding to the VIF originating the packet, if specified. TheInterface:external_ids:encap-ipsetting of the VIF is also populated to thePort_Bindingtable in the OVN SB database via theencapcolumn. Consequently, when a remote chassis needs to send a packet to a port-binding associated with this VIF, it utilizes the tunnel with the appropriateoptions:remote_ipthat matches theipinPort_Binding:encap. This mechanism is particularly beneficial for chassis with multiple physical interfaces designated for tunneling, where each interface is optimized for handling specific traffic associated with particular VIFs.
external_ids:ovn-encap-ip-default-
When
ovn-encap-ipcontains multiple IPs, this field indicates the default one.
external_ids:ovn-encap-df_default-
indicates the DF flag handling of the encapulation. Set to
trueto set the DF flag for new data paths orfalseto clear the DF flag.
external_ids:ovn-bridge-mappings-
A list of key-value pairs that map a physical network name to a local ovs bridge that provides connectivity to that network. An example value mapping two physical network names to two ovs bridges would be:
physnet1:br-eth0,physnet2:br-eth1.
external_ids:ovn-encap-csum-
ovn-encap-csumindicates that encapsulation checksums can be transmitted and received with reasonable performance. It is a hint to senders transmitting data to this chassis that they should use checksums to protect OVN metadata. Set totrueto enable orfalseto disable. Depending on the capabilities of the network interface card, enabling encapsulation checksum may incur performance loss. In such cases, encapsulation checksums can be disabled.
external_ids:ovn-encap-tos-
ovn-encap-tosindicates the value to be applied to OVN tunnel interface’s option:tos as specified in the Open_vSwitch database Interface table. Please refer to Open VSwitch Manual for details.
external_ids:ovn-cms-options-
A list of options that will be consumed by the CMS Plugin and which specific to this particular chassis. An example would be:
cms_option1,cms_option2:foo.
external_ids:ovn-transport-zones-
The transport zone(s) that this chassis belongs to. Transport zones is a way to group different chassis so that tunnels are only formed between members of the same group(s). Multiple transport zones may be specified with a comma-separated list. For example: tz1,tz2,tz3.
-
If not set, the Chassis will be considered part of a default transport zone.
external_ids:ovn-chassis-mac-mappings-
A list of key-value pairs that map a chassis specific mac to a physical network name. An example value mapping two chassis macs to two physical network names would be:
physnet1:aa:bb:cc:dd:ee:ff,physnet2:a1:b2:c3:d4:e5:f6. These are the macs that ovn-controller will replace a router port mac with, if packet is going from a distributed router port on vlan type logical switch.
external_ids:ovn-is-interconn-
The boolean flag indicates if the chassis is used as an interconnection gateway.
external_ids:ovn-match-northd-version-
The boolean flag indicates if
ovn-controllerneeds to checkovn-northdversion. If this flag is set to true and theovn-northd’sversion (reported in the Southbound database) doesn’t match with theovn-controller’sinternal version, then it will stop processing the southbound and local Open vSwitch database changes. The default value is considered false if this option is not defined.
external_ids:ovn-ofctrl-wait-before-clear-
The time, in milliseconds, to wait before clearing flows in OVS after OpenFlow connection/reconnection during
ovn-controllerinitialization. The purpose of this wait is to give time forovn-controllerto compute the new flows before clearing existing ones, to avoid data plane down time duringovn-controllerrestart/upgrade at large scale environments where recomputing the flows takes more than a few seconds or even longer. It is difficult forovn-controllerto determine when the new flows computing is completed, because of the dynamics in the cloud environments, which is why this configuration is provided for users to adjust based on the scale of the environment. By default, it is 0, which means clearing existing flows without waiting. Not setting the value, or setting it too small, may result in data plane down time during upgrade/restart, while setting it too big may result in unnecessary extra control plane latency of applying new changes of CMS during upgrade/restart. In most cases, a slightly bigger value is not harmful, because the extra control plane latency happens only once during the OpenFlow connection. To get a reasonable range of the value setting, it is recommended to run the below commands on a node in the target environment and then set this configuration to twice the value ofMaximumshown in the output of the second command.- •
-
ovn-appctl -t ovn-controller inc-engine/recompute
- •
-
ovn-appctl -t ovn-controller stopwatch/show flow-generation
external_ids:ovn-enable-lflow-cache-
The boolean flag indicates if
ovn-controllershould enable/disable the logical flow in-memory cache it uses when processing Southbound database logical flow changes. By default caching is enabled.
external_ids:ovn-limit-lflow-cache-
When used, this configuration value determines the maximum number of logical flow cache entries
ovn-controllermay create when the logical flow cache is enabled. By default the size of the cache is unlimited.
external_ids:ovn-memlimit-lflow-cache-kb-
When used, this configuration value determines the maximum size of the logical flow cache (in KB)
ovn-controllermay create when the logical flow cache is enabled. By default the size of the cache is unlimited.
external_ids:ovn-trim-limit-lflow-cache-
When used, this configuration value sets the minimum number of entries in the logical flow cache starting with which automatic memory trimming is performed. By default this is set to 10000 entries.
external_ids:ovn-trim-wmark-perc-lflow-cache-
When used, this configuration value sets the percentage from the high watermark number of entries in the logical flow cache under which automatic memory trimming is performed. E.g., if the trim watermark percentage is set to 50%, automatic memory trimming happens only when the number of entries in the logical flow cache gets reduced to less than half of the last measured high watermark. By default this is set to 50.
external_ids:ovn-trim-timeout-ms-
When used, this configuration value specifies the time, in milliseconds, since the last logical flow cache operation after which
ovn-controllerperforms memory trimming regardless of how many entries there are in the cache. By default this is set to 30000 (30 seconds).
external_ids:garp-max-timeout-sec-
When used, this configuration value specifies the maximum timeout (in seconds) between two consecutive GARP packets sent by
ovn-controller.ovn-controllerby default sends just 4 GARP packets with an exponential backoff timeout. Settingexternal_ids:garp-max-timeout-secallows to cap for the exponential backoff used byovn-controllerto send GARPs packets.
external_ids:arp-nd-max-timeout-sec-
When used, this configuration value specifies the maximum timeout (in seconds) between two consecutive ARP/ND packets sent by
ovn-controllerto resolve ECMP nexthop mac address.ovn-controllerby default continuously sends ARP/ND packets. Settingexternal_ids:arp-nd-max-timeout-secallows to cap for the exponential backoff used byovn-controllerto send ARPs/NDs packets.
external_ids:ovn-bridge-remote-
Connection to the OVN management bridge in OvS. It defaults to
unix:br-int.mgmtwhen not specified.
external_ids:ovn-bridge-remote-probe-interval-
The inactivity probe interval of the connection to the OVN management bridge, in milliseconds. It defaults to zero. If the value is zero, it disables the inactivity probe.
external_ids:dynamic-routing-port-mapping-
This setting works together with the Northbound dynamic-routing-port-name option on Logical_Router_Ports. See the ovn-nb(5) for more details.
Most of configuration options listed above can also be set for a particular chassis name (see external_ids:system-id for more information). This can be achieved by setting external_ids:option-[chassis] instead of external_ids:option. For example, set external_ids:ovn-encap-ip-otherhv to use a particular IP address for the controller instance named otherhv. Name specific configuration options always override any global options set in the database.
Chassis-specific configuration options in the database plus the ability to configure the chassis name to use via the system-id-override file or command line allows to run multiple ovn-controller instances with unique chassis names on the same host using the same vswitchd instance. This may be useful when running a hybrid setup with more than one CMS managing ports on the host, or to use different datapath types on the same host. Also note that this ability is highly experimental and has known limitations (for example, stateful ACLs are not supported). Use at your own risk.
ovn-controller reads the following values from the Open_vSwitch database of the local OVS instance:
datapath-typefromBridgetable-
This value is read from local OVS integration bridge row of
Bridgetable and populated inother_config:datapath-typeof theChassistable in the OVN_Southbound database.
iface-typesfromOpen_vSwitchtable-
This value is populated in
external_ids:iface-typesof theChassistable in the OVN_Southbound database.
private_key,certificate,ca_cert, andbootstrap_ca_certfrom SSL table-
These values provide the SSL/TLS configuration used for connecting to the OVN southbound database server when an SSL/TLS connection type is configured via
external_ids:ovn-remote. Note that this SSL/TLS configuration can also be provided via command-line options, the configuration in the database takes precedence if both are present.
Open vswitch database usage
ovn-controller uses a number of external_ids keys in the Open vSwitch database to keep track of ports and interfaces. For proper operation, users should not change or clear these keys:
external_ids:ovn-chassis-idin thePorttable-
The presence of this key identifies a tunnel port within the integration bridge as one created by
ovn-controllerto reach a remote chassis. Its value is the chassis ID of the remote chassis.
external_ids:ct-zone-rangein theOpen_vSwitchtable-
The presence of this key identifies a minimum and maximum values for ct-zone ids dynamically selected by ovn-controller (boundaries are included in the range). Minimum value is 1 while maximum value is 65535.
external_ids:ct-zone-*in theBridgetable-
Logical ports and gateway routers are assigned a connection tracking zone by
ovn-controllerfor stateful services. To keep state across restarts ofovn-controller, these keys are stored in the integration bridge’s Bridge table. The name contains a prefix ofct-zone-followed by the name of the logical port or gateway router’s zone key. The value for this key identifies the zone used for this port.
external_ids:ovn-localnet-portin thePorttable-
The presence of this key identifies a patch port as one created by
ovn-controllerto connect the integration bridge and another bridge to implement alocalnetlogical port. Its value is the name of the logical port withtypeset tolocalnetthat the port implements. Seeexternal_ids:ovn-bridge-mappings, above, for more information.
-
Each
localnetlogical port is implemented as a pair of patch ports, one in the integration bridge, one in a different bridge, with the sameexternal_ids:ovn-localnet-portvalue.
external_ids:ovn-l2gateway-portin thePorttable-
The presence of this key identifies a patch port as one created by
ovn-controllerto connect the integration bridge and another bridge to implement al2gatewaylogical port. Its value is the name of the logical port withtypeset tol2gatewaythat the port implements. Seeexternal_ids:ovn-bridge-mappings, above, for more information.
-
Each
l2gatewaylogical port is implemented as a pair of patch ports, one in the integration bridge, one in a different bridge, with the sameexternal_ids:ovn-l2gateway-portvalue.
external-ids:ovn-l3gateway-portin thePorttable-
This key identifies a patch port as one created by
ovn-controllerto implement al3gatewaylogical port. Its value is the name of the logical port with type set tol3gateway. This patch port is similar to the OVN logical patch port, except thatl3gatewayport can only be bound to a particular chassis.
external-ids:ovn-logical-patch-portin thePorttable-
This key identifies a patch port as one created by
ovn-controllerto implement an OVN logical patch port within the integration bridge. Its value is the name of the OVN logical patch port that it implements.
external-ids:ovn-startup-tsin theBridgetable-
This key represents the timestamp (in milliseconds) at which
ovn-controllerprocess was started.
external-ids:ovn-nb-cfgin theBridgetable-
This key represents the last known
OVN_Southbound.SB_Global.nb_cfgvalue for which all flows have been successfully installed in OVS.
external-ids:ovn-nb-cfg-tsin theBridgetable-
This key represents the timestamp (in milliseconds) of the last known
OVN_Southbound.SB_Global.nb_cfgvalue for which all flows have been successfully installed in OVS.
external_ids:ovn-installedandexternal_ids:ovn-installed-tsin theInterfacetable-
This key is set after all openflow operations corresponding to the OVS interface have been processed by ovs-vswitchd. At the same time a timestamp, in milliseconds since the epoch, is stored in
external_ids:ovn-installed-ts.
Ovn southbound database usage
ovn-controller reads from much of the OVN_Southbound database to guide its operation. ovn-controller also writes to the following tables:
Chassis-
Upon startup,
ovn-controllercreates a row in this table to represent its own chassis. Upon graceful termination, e.g. with ovs-appctl -t ovn-controller exit (but not SIGTERM),ovn-controllerremoves its row.
Encap-
Upon startup,
ovn-controllercreates a row or rows in this table that represent the tunnel encapsulations by which its chassis can be reached, and points itsChassisrow to them. Upon graceful termination,ovn-controllerremoves these rows.
Port_Binding-
At runtime,
ovn-controllersets thechassiscolumns of ports that are resident on its chassis to point to itsChassisrow, and, conversely, clears thechassiscolumn of ports that point to itsChassisrow but are no longer resident on its chassis. Thechassiscolumn has a weak reference type, so whenovn-controllergracefully exits and removes itsChassisrow, the database server automatically clears any remaining references to that row.
MAC_Binding-
At runtime,
ovn-controllerupdates theMAC_Bindingtable as instructed byput_arpandput_ndlogical actions. These changes persist beyond the lifetime ofovn-controller.
Runtime management commands
ovs-appctl can send commands to a running ovn-controller process. The currently supported commands are described below.
exit-
Causes
ovn-controllerto gracefully terminate.
ct-zone-list-
Lists each local logical port and its connection tracking zone.
meter-table-list-
Lists each meter table entry and its local meter id.
group-table-list-
Lists each group table entry and its local group id.
inject-pktmicroflow-
Injects microflow into the connected Open vSwitch instance. microflow must contain an ingress logical port (
inportargument) that is present on the Open vSwitch instance.
-
The microflow argument describes the packet whose forwarding is to be simulated, in the syntax of an OVN logical expression, as described in ovn-sb(5), to express constraints. The parser understands prerequisites; for example, if the expression refers to
ip4.src, there is no need to explicitly stateip4or eth.type ==0x800.
connection-status-
Show OVN SBDB connection status for the chassis.
recompute-
Trigger a full compute iteration in
ovn-controllerbased on the contents of the Southbound database and local OVS database.
-
This command is intended to use only in the event of a bug in the incremental processing engine in
ovn-controllerto avoid inconsistent states. It should therefore be used with care as full recomputes are cpu intensive.
sb-cluster-state-reset-
Reset southbound database cluster status when databases are destroyed and rebuilt.
-
If all databases in a clustered southbound database are removed from disk, then the stored index of all databases will be reset to zero. This will cause ovn-controller to be unable to read or write to the southbound database, because it will always detect the data as stale. In such a case, run this command so that ovn-controller will reset its local index so that it can interact with the southbound database again.
debug/delay-nb-cfg-reportseconds-
This command is used to delay ovn-controller updating the
nb_cfgback toOVN_Southbounddatabase. This is useful when ovn-nbctl --wait=hv is used to measure end-to-end latency in a large scale environment. See ovn-nbctl(8) for more details.
lflow-cache/flush-
Flushes the
ovn-controllerlogical flow cache.
lflow-cache/show-stats-
Displays logical flow cache statistics: enabled/disabled, per cache type entry counts.
inc-engine/show-stats-
Display
ovn-controllerengine counters. For each engine node the following counters have been added:- •
-
recompute
- •
-
compute
- •
-
cancel
- inc-engine/show-stats engine_node_name counter_name
-
Display the
ovn-controllerengine counter(s) for the specified engine_node_name. counter_name is optional and can be one ofrecompute,computeorcancel.
inc-engine/clear-stats-
Reset
ovn-controllerengine counters.
Releases
4 releases since Debian 9 (Stretch); the text changed 3 times.
--bootstrap-ca-cert since Debian 10 (Buster);
--ca-cert since Debian 10 (Buster);
--certificate since Debian 10 (Buster);
--detach since Debian 10 (Buster);
--help since Debian 10 (Buster);
--log-file since Debian 10 (Buster);
--monitor since Debian 10 (Buster);
--no-chdir since Debian 10 (Buster);
--no-self-confinement since Debian 10 (Buster);
--overwrite-pidfile since Debian 10 (Buster);
--peer-ca-cert since Debian 10 (Buster);
--pidfile since Debian 10 (Buster);
--private-key since Debian 10 (Buster);
--syslog-method since Debian 10 (Buster);
--syslog-target since Debian 10 (Buster);
--unixctl since Debian 13 (Trixie);
--user since Debian 10 (Buster);
--verbose since Debian 10 (Buster);
--version since Debian 10 (Buster);
-C since Debian 10 (Buster);
-V since Debian 10 (Buster);
-c since Debian 10 (Buster);
-h since Debian 10 (Buster);
-p since Debian 10 (Buster);
-v since Debian 10 (Buster).