nvme-micron-id-ctrl1
Send nvme identify controller with micron vendor-specific fields
Usage
nvme [<global-options>]
micron
id-ctrl
<device>
Overview
For the NVMe device given, sends an identify controller command and provides the result with Micron vendor-specific fields decoded.
The <device> parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1).
This command extends the standard Identify Controller output with Micron-specific fields:
PMS (Power Measurement Support)
Bit 21 of CTRATT (Controller Attributes). Indicates whether the controller supports power measurement.
IPMSR (Interval Power Measurement Sample Rate)
Located at bytes 392-393 in the Identify Controller reserved area. Specifies the sample rate for interval power measurement.
MSMT (Maximum Stop Measurement Time)
Located at bytes 394-395 in the Identify Controller reserved area. Specifies the maximum time to stop power measurement.
Options
Options
The following options are defined at the top-level nvme command and are available to this subcommand:
-
--dry-run -
Print the command that would be executed, but do not actually execute it.
-
--no-ioctl-probing -
Disable probing for 64-bit IOCTL support.
-
--no-retries -
Disable retry logic on transient errors.
-
-o <fmt>, --output-format=<fmt> -
Set the reporting format to normal, tabular, 'json, or binary. Only one output format may be used at a time.
-
--output-format-version=<version> -
Select the output format version. Version 1 uses the original field naming, while version 2 (default) provides more consistent and script-friendly field names. Other versions are rejected.
-
--quiet -
Suppress informational messages. Errors are still reported, and --quiet cancels any --verbose for the library log level.
-
--set-options=<key=value>[,<key=value>...] -
Set libnvme library options for this invocation. Supported keys are force-4k, mi-probe-enabled, test-base-dir and test-sysfs-dir.
-
--timeout=<ms> -
Set the timeout for the command in milliseconds. infinite or -1 waits without a time limit (0xffffffff).
-
-v, --verbose -
Increase the level of detail in the output. May be specified multiple times to further increase verbosity.
These options can also be set as machine-wide defaults in nvme-cli.conf(5). A command-line flag always overrides the file.
Examples
• Display Identify Controller in human-readable format:
# nvme micron id-ctrl /dev/nvme0
• Display Identify Controller in JSON format:
# nvme micron id-ctrl /dev/nvme0 -o json
Nvme
Part of the nvme-user suite