nvme-config-create1
Add an nvme-of connection entry to the ini configuration
Usage
nvme [<global-options>]
config
create
[--discovery]
[--persistent
[{=<no | auto | force>}]]
[--host-symname=<name>]
[--output=<file>]
[<fabrics-options>]
Overview
Build one NVMe-oF connection entry from command-line options and add it to the INI configuration used by nvme connect, nvme discover, and nvme connect-all. The format is documented at https://github.com/linux-nvme/nvme-cli/blob/master/libnvme/design/CONFIG.md
If the target file exists, its connections are kept and the new entry is merged in alongside them. Running the same command again is a no-op. Unlike nvme config convert, this is not a one-shot migration; it is the ongoing way to build an INI configuration from the command line.
The entry is an I/O controller (subsystem) entry by default, and --nqn is required. Use --discovery for a discovery controller entry instead; --nqn is then optional.
A connection with an explicit --hostnqn or --hostid is written to a drop-in under <file>.d/. One without either goes into the main file.
Options
-
--discovery -
Create a discovery controller entry instead of an I/O controller entry. Without this, --nqn is required.
-
--persistent[=<no|auto|force>] -
Record this discovery controller’s persistence mode. Requires --discovery. Because the value is optional, it must be attached directly to the option (--persistent=force). A value given as a separate argument (--persistent force) is no value of the option but an extra argument, and the command fails.
• auto (the default for every --discovery entry, whether or not --persistent is given): persist the connection only where the target’s own EPCSD (Explicit Persistent Connection Support for Discovery) flag reports support for it.
• force: persist regardless of what EPCSD reports, for a target whose self-reported EPCSD cannot be trusted.
• no: explicitly record that this discovery controller is not persistent, overriding any default that would otherwise apply.
-
--host-symname=<name> -
Name this host persona. Puts it in its own configuration drop-in.
-
--output=<file> -
Write to this file instead of the default /usr/local/etc/nvme/nvme-fabrics.conf.
Options
The following options are common to NVMe over Fabrics commands such as nvme connect:
-
-a <traddr>, --traddr=<traddr> -
Specify the network address of the controller. For transports using IP addressing (e.g. rdma, tcp), this should be an IP address.
-
--concat -
Enable secure concatenation (TCP).
-
-c <#>, --reconnect-delay=<#> -
Set the delay in seconds before reconnect is attempted after a connection loss.
-
-C <secret>, --kxchap-ctrl-secret=<secret> -
Controller authentication secret for bi-directional authentication. If not specified, bi-directional authentication is not attempted.
-
-S <secret>, --kxchap-secret=<secret> -
Host authentication secret (KX-HMAC-CHAP). Must be provided in ASCII format as defined in the NVMe specification.
-
-C <secret>, --dhchap-ctrl-secret=<secret> -
Controller authentication secret for bi-directional authentication. If not specified, bi-directional authentication is not attempted. (deprecated, see --kxchap-ctrl-secret)
-
-S <secret>, --dhchap-secret=<secret> -
Host authentication secret (DH-HMAC-CHAP). Must be provided in ASCII format as defined in the NVMe specification. (deprecated, see --kxchap-secret)
-
--disable-sqflow -
Disable submission queue flow control.
-
-G, --data-digest -
Enable data digest generation/verification (TCP).
-
-D, --duplicate-connect -
Allow duplicate connections to the same subsystem.
-
-g, --hdr-digest -
Enable header digest generation/verification (TCP).
-
-f <iface>, --host-iface=<iface> -
Specify the network interface to use for the connection.
-
-I <hostid>, --hostid=<hostid> -
Specify the host UUID.
-
-q <hostnqn>, --hostnqn=<hostnqn> -
Override the default host NQN.
-
-w <traddr>, --host-traddr=<traddr> -
Specify the source address on the host side of the connection.
-
-k <#>, --keep-alive-tmo=<#> -
Set the keep-alive timeout in seconds.
-
--keyring=<keyring> -
Keyring to use for TLS key lookup.
-
-n <subnqn>, --nqn=<subnqn> -
Specify the NVMe subsystem NQN to connect to.
-
-i <#>, --nr-io-queues=<#> -
Number of I/O queues to create.
-
-P <#>, --nr-poll-queues=<#> -
Number of polling queues to create.
-
-W <#>, --nr-write-queues=<#> -
Number of write queues to create.
-
-Q <#>, --queue-size=<#> -
Queue depth for I/O queues.
-
-l <#>, --ctrl-loss-tmo=<#> -
Maximum time in seconds to retry reconnect attempts after controller loss.
-
-s <trsvcid>, --trsvcid=<trsvcid> -
Transport service identifier (e.g. TCP/rdma port). Default is 4420 for RDMA.
-
-T <#>, --tos=<#> -
Type of service value for the connection (TCP).
-
-t <trtype>, --transport=<trtype> -
Specify the transport type. Supported values include:
+
| Value | Description |
| rdma | RDMA (RoCE, iWARP, InfiniBand) |
| tcp | TCP/IP |
| fc | Fibre Channel (experimental) |
| loop | Local loopback transport |
-
--tls -
Enable TLS encryption (TCP).
-
--tls-key=<tls-key> -
TLS key for the connection. It is recommended to preload keys into the system keyring instead of passing them via the command line.
-
--tls-key-identity=<identity> -
Identity associated with the TLS key.
Options
The following options are defined at the top-level nvme command and are available to this subcommand:
-
--dry-run -
Print the command that would be executed, but do not actually execute it.
-
--no-ioctl-probing -
Disable probing for 64-bit IOCTL support.
-
--no-retries -
Disable retry logic on transient errors.
-
-o <fmt>, --output-format=<fmt> -
Set the reporting format to normal, tabular, 'json, or binary. Only one output format may be used at a time.
-
--output-format-version=<version> -
Select the output format version. Version 1 uses the original field naming, while version 2 (default) provides more consistent and script-friendly field names. Other versions are rejected.
-
--quiet -
Suppress informational messages. Errors are still reported, and --quiet cancels any --verbose for the library log level.
-
--set-options=<key=value>[,<key=value>...] -
Set libnvme library options for this invocation. Supported keys are force-4k, mi-probe-enabled, test-base-dir and test-sysfs-dir.
-
--timeout=<ms> -
Set the timeout for the command in milliseconds. infinite or -1 waits without a time limit (0xffffffff).
-
-v, --verbose -
Increase the level of detail in the output. May be specified multiple times to further increase verbosity.
These options can also be set as machine-wide defaults in nvme-cli.conf(5). A command-line flag always overrides the file.
Examples
• Add a discovery controller entry for an FC discovery controller:
# nvme config create --transport fc \
--traddr=nn-0x58ccf090c92006da:pn-0x58ccf091492806da \
--host-traddr=nn-0x20000024ff7fa448:pn-0x21000024ff7fa448 \
--hostnqn=nqn.2014-08.org.nvmexpress:uuid:62a4ab74-1e18-11f1-8bb7-6c1ff71ba506 \
--discovery
• Add an I/O controller entry to a test configuration file:
# nvme config create --transport tcp --traddr=192.168.1.20 --trsvcid=4420 \
--nqn=nqn.2024-01.com.example:data.vol1 \
--output=/tmp/nvme-fabrics.conf
Nvme