named-checkzone1
Zone file validity checking or converting tool
Usage
named-checkzone [-d]
[-h]
[-j]
[-q]
[-v]
[-c
class]
[-C
mode]
[-f
format]
[-F
format]
[-J
filename]
[-i
mode]
[-k
mode]
[-m
mode]
[-M
mode]
[-n
mode]
[-l
ttl]
[-L
serial]
[-o
filename]
[-r
mode]
[-s
style]
[-S
mode]
[-t
directory]
[-T
mode]
[-w
directory]
[-D]
[-W
mode]
zonename
filename
Overview
named-checkzone checks the syntax and integrity of a zone file. It performs the same checks as named <#std-iscman-named> does when loading a zone. This makes named-checkzone useful for checking zone files before configuring them into a name server.
Options
-
-d -
This option enables debugging.
-
-h -
This option prints the usage summary and exits.
-
-q -
This option sets quiet mode, which only sets an exit code to indicate successful or failed completion.
-
-v -
This option prints the version of the
named-checkzoneprogram and exits.
-
-j -
When loading a zone file, this option tells
named<#std-iscman-named> to read the journal if it exists. The journal file name is assumed to be the zone file name with the string.jnlappended.
-
-J filename -
When loading the zone file, this option tells
named<#std-iscman-named> to read the journal from the given file, if it exists. This implies-j.
-
-c class -
This option specifies the class of the zone. If not specified, IN is assumed.
-
-C mode -
This option controls check mode on zone files when loading. Possible modes are
check-svcb:failandcheck-svcb:ignore.check-svcb:failturns on additional checks on_dnsSVCB records andcheck-svcb:ignoredisables these checks. The default ischeck-svcb:fail.
-
-i mode -
This option performs post-load zone integrity checks. Possible modes are
full(the default),full-sibling,local,local-sibling, andnone.Mode
fullchecks that MX records refer to A or AAAA records (both in-zone and out-of-zone hostnames). Modelocalonly checks MX records which refer to in-zone hostnames.Mode
fullchecks that SRV records refer to A or AAAA records (both in-zone and out-of-zone hostnames). Modelocalonly checks SRV records which refer to in-zone hostnames.Mode
fullchecks that delegation NS records refer to A or AAAA records (both in-zone and out-of-zone hostnames). It also checks that glue address records in the zone match those advertised by the child. Modelocalonly checks NS records which refer to in-zone hostnames or verifies that some required glue exists, i.e., when the name server is in a child zone.Modes
full-siblingandlocal-siblingdisable sibling glue checks, but are otherwise the same asfullandlocal, respectively.Mode
nonedisables the checks.
-
-f format -
This option specifies the format of the zone file. Possible formats are
text(the default), andraw.
-
-F format -
This option specifies the format of the output file specified. For
named-checkzone, this does not have any effect unless it dumps the zone contents.Possible formats are
text(the default), which is the standard textual representation of the zone, andrawandraw=N, which store the zone in a binary format for rapid loading bynamed<#std-iscman-named>.raw=Nspecifies the format version of the raw zone file: if N is 0, the raw file can be read by any version ofnamed<#std-iscman-named>; if N is 1, the file can only be read by release 9.9.0 or higher. The default is 1.
-
-k mode -
This option performs
check-nameschecks with the specified failure mode. Possible modes arefail,warn(the default), andignore.
-
-l ttl -
This option sets a maximum permissible TTL for the input file. Any record with a TTL higher than this value causes the zone to be rejected. This is similar to using the
max-zone-ttloption innamed.conf<#std-iscman-named.conf>.
-
-L serial -
When compiling a zone to
rawformat, this option sets the "source serial" value in the header to the specified serial number. This is expected to be used primarily for testing purposes.
-
-m mode -
This option specifies whether MX records should be checked to see if they are addresses. Possible modes are
fail,warn(the default), andignore.
-
-M mode -
This option checks whether a MX record refers to a CNAME. Possible modes are
fail,warn(the default), andignore.
-
-n mode -
This option specifies whether NS records should be checked to see if they are addresses. Possible modes are
fail,warn(the default), andignore.
-
-o filename -
This option writes the zone output to
filename. Iffilenameis-, then the zone output is written to standard output.
-
-r mode -
This option checks for records that are treated as different by DNSSEC but are semantically equal in plain DNS. Possible modes are
fail,warn(the default), andignore.
-
-s style -
This option specifies the style of the dumped zone file. Possible styles are
full(the default) andrelative. Thefullformat is most suitable for processing automatically by a separate script. The relative format is more human-readable and is thus suitable for editing by hand. This does not have any effect unless it dumps the zone contents. It also does not have any meaning if the output format is not text.
-
-S mode -
This option checks whether an SRV record refers to a CNAME. Possible modes are
fail,warn(the default), andignore.
-
-t directory -
This option tells
named<#std-iscman-named> to chroot todirectory, so thatincludedirectives in the configuration file are processed as if run by a similarly chrootednamed<#std-iscman-named>.
-
-T mode -
This option checks whether Sender Policy Framework (SPF) records exist and issues a warning if an SPF-formatted TXT record is not also present. Possible modes are
warn(the default) andignore.
-
-w directory -
This option instructs
named<#std-iscman-named> to chdir todirectory, so that relative filenames in master file $INCLUDE directives work. This is similar to the directory clause innamed.conf<#std-iscman-named.conf>.
-
-D -
This option dumps the zone file in canonical format.
-
-W mode -
This option specifies whether to check for non-terminal wildcards. Non-terminal wildcards are almost always the result of a failure to understand the wildcard matching algorithm (RFC 4592 <https://datatracker.ietf.org/doc/html/rfc4592.html>). Possible modes are
warn(the default) andignore.
zonename-
This indicates the domain name of the zone being checked.
filename-
This is the name of the zone file.
Return values
named-checkzone returns an exit status of 1 if errors were detected and 0 otherwise.
Releases
3 releases since Debian 12 (Bookworm); the text changed 2 times.
-C since Debian 13 (Trixie).