muse_standard7
Create a flux response curve from a standard star exposure.
Usage
esorex muse_standard [OPTIONS] FILE.sof
Overview
Merge pixel tables from all IFUs and correct for differential atmospheric refraction, when necessary. To derive the flux response curve, integrate the flux of all objects detected within the field of view using the given profile. Select one object as the standard star (either the brightest or the one nearest one, depending on --select) and compare its measured fluxes to tabulated fluxes to derive the sensitivity over wavelength. Postprocess this sensitivity curve to mark wavelength ranges affected by telluric absorption. Interpolate over the telluric regions and derive a telluric correction spectrum for them. The final response curve is then linearly extrapolated to the largest possible MUSE wavelength range and smoothed (with the method given by --smooth). The derivation of the telluric correction spectrum assumes that the star has a smooth spectrum within the telluric regions. If there are more than one exposure given in the input data, the derivation of the flux response and telluric corrections are done separately for each exposure. For each exposure, an image containing the extracted stellar spectra and the datacube used for flux integration are saved, together with collapsed images for each given filter. In MUSE´s WFM data (both AO and non-AO), the Moffat profile is a good approximation of the actual PSF. Using the smoothed profile ("smoffat") helps to increase the S/N and in most cases removes systematics. In NFM, however, the profile is a combination of a wide PSF plus the central AO-corrected peak, which cannot be fit well by an analytical profile. In this case the circular aperture is the best way to extract the flux. Using --profile="auto" (the default) selects these options to give the best flux extraction for most cases.
Options
-
--profile <str> -
Type of flux integration to use. "gaussian", "moffat", and "smoffat" use 2D profile fitting, "circle" and "square" are non-optimal aperture flux integrators. "smoffat" uses smoothing of the Moffat parameters from an initial fit, to derive physically meaningful wavelength- dependent behavior. "auto" selects the smoothed Moffat profile for WFM data and circular flux integration for NFM. (str; default: ´auto´). The full name of this option for the EsoRex configuration file is
muse.muse_standard.profile[default = auto].
-
--select <str> -
How to select the star for flux integration, "flux" uses the brightest star in the field, "distance" uses the detection nearest to the approximate coordinates of the reference source. (str; default: ´distance´). The full name of this option for the EsoRex configuration file is
muse.muse_standard.select[default = distance].
-
--smooth <str> -
How to smooth the response curve before writing it to disk. "none" does not do any kind of smoothing (such a response curve is only useful, if smoothed externally; "median" does a median-filter of 15 Angstrom half-width; "ppoly" fits piecewise cubic polynomials (each one across 2x150 Angstrom width) postprocessed by a sliding average filter of 15 Angstrom half-width. (str; default: ´ppoly´). The full name of this option for the EsoRex configuration file is
muse.muse_standard.smooth[default = ppoly].
-
--lambdamin <float> -
Cut off the data below this wavelength after loading the pixel table(s). (float; default: 4000.0). The full name of this option for the EsoRex configuration file is
muse.muse_standard.lambdamin[default = 4000.0].
-
--lambdamax <float> -
Cut off the data above this wavelength after loading the pixel table(s). (float; default: 10000.0). The full name of this option for the EsoRex configuration file is
muse.muse_standard.lambdamax[default = 10000.0].
-
--lambdaref <float> -
Reference wavelength used for correction of differential atmospheric refraction. The R-band (peak wavelength ~7000 Angstrom) that is usually used for guiding, is close to the central wavelength of MUSE, so a value of 7000.0 Angstrom should be used if nothing else is known. A value less than zero switches DAR correction off. (float; default: 7000.0). The full name of this option for the EsoRex configuration file is
muse.muse_standard.lambdaref[default = 7000.0].
-
--darcheck <str> -
Carry out a check of the theoretical DAR correction using source centroiding. If "correct" it will also apply an empirical correction. (str; default: ´none´). The full name of this option for the EsoRex configuration file is
muse.muse_standard.darcheck[default = none].
-
--filter <str> -
The filter name(s) to be used for the output field-of-view image. Each name has to correspond to an EXTNAME in an extension of the FILTER_LIST file. If an unsupported filter name is given, creation of the respective image is omitted. If multiple filter names are given, they have to be comma separated. If the zeropoint QC parameters are wanted, make sure to add "Johnson_V,Cousins_R,Cousins_I". (str; default: ´white´). The full name of this option for the EsoRex configuration file is
muse.muse_standard.filter[default = white].
Note that it is possible to create a configuration file containing these options, along with suitable default values. Please refer to the details provided by the 'esorex --help' command.
Version
muse_standard 2.8.7
Releases
4 releases since Debian 9 (Stretch); the text changed 3 times.