SYNOPSIS

General EE device

EE [.]XXXXXXXXXXXX[XX][/[ temperature | version | type_number | temperature_offset | address | crc8 | id | locator | r_address | r_id | r_locator | type ]]

UVI sensor

EE [.]XXXXXXXXXXXX[XX][/[ UVI/UVI | UVI/UVI_offset | UVI/in_case | UVI/valid | temperature | version | type_number | temperature_offset ]]

General EF device

EF [.]XXXXXXXXXXXX[XX][/[ version | type_number | address | crc8 | id | locator | r_address | r_id | r_locator | type ]]

Moisture Meter

moisture/sensor.[0-3|ALL]

moisture/is_moisture.[0-3|ALL|BYTE] | moisture/is_leaf.[0-3|ALL|BYTE]

moisture/calibrate/min | moisture/calibrate/max | moisture/calibrate/raw.[0-4|ALL]

Hub

hub/branch.[0-3|ALL|BYTE] | hub/short.[0-3|ALL|BYTE]

FAMILY CODE

EE

Device with temperature

EE

UVI

EF

Device without temperature

EF

Moisture Meter

EF

Hub

TEMPERATURE PROPERTIES

temperature

read-only, floating point

Temperature read every 30 seconds. Resolution .5C (uses an on-board DS18B20). Temperature is only present in the EE-series devices.

temperature_offset

read-write, floating point

Offset stored on device to apply to temperature readings.

UVI PROPERTIES

UVI/UVI

read-only floating point

UV Index (ultraviolet index) in the range 0.0 to 16.0 resolution .1

Only the UVI version of the EE device has a UVI sensor. Readings made every .5 seconds.

UVI/UVI_offset

read-write, floating point

Signed offset to apply to the UVI measurement. Stored on-device non-volatile.

UVI/in_case

read-write, yes-no

Flag to apply compensation for the protective case. Stored on-device non-volatile.

UVI/valid

read-only, yes-no Flag the the EE device type matches the known UVI type.

Moisture Meter

moisture/sensor.0 .. moisture/sensor.3 moisture/sensor.ALL

read-only integer

Up to 4 sensors reading moisture can be attached. OWFS addresses the sensors as 0 through 3 while the datasheet uses 1-4. Two types of external sensors are supported (and the data range):

Watermark Soil Moisture Sensor

0-199

Leaf Wetness Sensor

0-99

moisture/is_moisture.0 .. moisture/is_moisture.3 moisture/is_moisture.ALL

moisture/is_leaf.0 .. moisture/is_leaf.3 moisture/is_leaf.ALL

read-write yes_no

Set or get the type of sensor attached to each channel. Note that OWFS addresses the sensors as 0 through 3 while the datasheet uses 1-4. Two types of external sensors are supported:

Watermark Soil Moisture

Sensor

Leaf Wetness

Sensor

Note that is_leaf and is_moisture are complementary and clearing one sets the other.

moisture/calibrate/min

moisture/calibrate/max

read-write unsigned integer

Set or get the upper and lower range for the raw data for leaf wetness scaling. See the datasheet for details.

moisture/calibrate/raw.0 .. moisture/calibrate/raw.3 moisture/calibrate/raw.ALL

read-only unsigned integer

Read the raw leaf wetness values for setting scaling. See the datasheet for details. Note that OWFS addresses the sensors as 0 through 3 while the datasheet uses 1-4.

Hub

4-channel hub. Individual branches can be switched on and off.

hub/branch.0 .. hub/branch.3 hub/branch.ALL hub/branch.BYTE

read-write, yes-no

The HobbyBoards hub has four 1-wire bus lines. Each branch is electricaly isolated from reflections and shorts, and can be optionally excluded from the 1-wire network.

You can turn each branch on or off by writing 0 (off) or 1 (on) to the corresponding property. Note that OWFS indexes the branches 0 to 3 while the datasheet uses 1 to 4.

The easiest way to turn all the branches on is to write 15 (0x0F) to hub/branch.BYTE

hub/short.0 .. hub/short.3 hub/short.ALL hub/short.BYTE

read-only, yes-no

Is the corresponding branch in "short" condition? (Electrically shorted out).

IDENTIFICATION PROPERTIES

version

read-only, ascii

Firmware version for the EE/EF device. Reported in nn.nn format where nn is major/minor decimal value.

Note: This format was changed as of version owfs-2.9p6 at the request of the HobbyBoards. Formerly reported in HH.HH format where HH is a hex digit (0-9A-F).

type_number

read-only, integer

Index of the type of sensor built into this device. Current known assignments:

1

UVI (Ultraviolet index)

2

Moisture meter

3

Moisture meter with datalogger

4

Sniffer

5

Hub

STANDARD PROPERTIES

address

r_address

read-only, ascii

The entire 64-bit unique ID. Given as upper case hexidecimal digits (0-9A-F).

address starts with the family code

r address is the address in reverse order, which is often used in other applications and labeling.

crc8

read-only, ascii

The 8-bit error correction portion. Uses cyclic redundancy check. Computed from the preceding 56 bits of the unique ID number. Given as upper case hexidecimal digits (0-9A-F).

family

read-only, ascii

The 8-bit family code. Unique to each type of device. Given as upper case hexidecimal digits (0-9A-F).

id

r_id

read-only, ascii

The 48-bit middle portion of the unique ID number. Does not include the family code or CRC. Given as upper case hexidecimal digits (0-9A-F).

r id is the id in reverse order, which is often used in other applications and labeling.

locator

r_locator

read-only, ascii

Uses an extension of the 1-wire design from iButtonLink company that associated 1-wire physical connections with a unique 1-wire code. If the connection is behind a Link Locator the locator will show a unique 8-byte number (16 character hexidecimal) starting with family code FE.

If no Link Locator is between the device and the master, the locator field will be all FF.

r locator is the locator in reverse order.

present (DEPRECATED)

read-only, yes-no

Is the device currently present on the 1-wire bus?

type

read-only, ascii

Part name assigned by Dallas Semi. E.g. DS2401 Alternative packaging (iButton vs chip) will not be distiguished.

ALARMS

None

DESCRIPTION

1-Wire

1-wire is a wiring protocol and series of devices designed and manufactured by Dallas Semiconductor, Inc. The bus is a low-power low-speed low-connector scheme where the data line can also provide power.

Each device is uniquely and unalterably numbered during manufacture. There are a wide variety of devices, including memory, sensors (humidity, temperature, voltage, contact, current), switches, timers and data loggers. More complex devices (like thermocouple sensors) can be built with these basic devices. There are also 1-wire devices that have encryption included.

The 1-wire scheme uses a single bus master and multiple slaves on the same wire. The bus master initiates all communication. The slaves can be individually discovered and addressed using their unique ID.

Bus masters come in a variety of configurations including serial, parallel, i2c, network or USB adapters.

OWFS design

OWFS is a suite of programs that designed to make the 1-wire bus and its devices easily accessible. The underlying priciple is to create a virtual filesystem, with the unique ID being the directory, and the individual properties of the device are represented as simple files that can be read and written.

Details of the individual slave or master design are hidden behind a consistent interface. The goal is to provide an easy set of tools for a software designer to create monitoring or control applications. There are some performance enhancements in the implementation, including data caching, parallel access to bus masters, and aggregation of device communication. Still the fundemental goal has been ease of use, flexibility and correctness rather than speed.

EE / EF

The EEEF (3) are a reference platform of microprocessor based 1-wire slaves. In general they require external power, and have an on-board index for the specific capabilities. They are designed by Eric Vickery at HobbyBoards.com

The EE class device uses family code EE and has an included temperature sensor. The EF devices have no temperature sensor,

UVI

The UVI sensor is an implementation of the EE class device with Ultra Violet Index sensing. All it's specific properties are in the UVI/ directory.

ADDRESSING

All 1-wire devices are factory assigned a unique 64-bit address. This address is of the form:

Family Code

8 bits

Address

48 bits

CRC

8 bits

Addressing under OWFS is in hexidecimal, of form:

  • 01.123456789ABC

where 01 is an example 8-bit family code, and 12345678ABC is an example 48 bit address.

The dot is optional, and the CRC code can included. If included, it must be correct.

DATASHEET

UVI

http://www.hobby-boards.com/catalog/links/uvi2-r1/UVI%20Meter%20User%20Manual.pdf

Moisture and Leaf Sensor

http://www.hobby-boards.com/download/manuals/Moisture%20Meter.pdf

4 Channel Hub

http://www.hobby-boards.com/download/manuals/4%20Channel%20Hub.pdf

RELATED TO EEEF…

Programs

owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread (1) owwrite (1) owpresent (1) owtap (1)

Configuration and testing

owfs (5) owtap (1) owmon (1)

Language bindings

owtcl (3) owperl (3) owcapi (3)

Clocks

DS1427 (3) DS1904(3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417 (3)

ID

DS2401 (3) DS2411 (3) DS1990A (3)

Memory

DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3) DS1995 (3) DS1996 (3) DS2430A (3) DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3) DS28E04 (3) DS28EC20 (3)

Switches

DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3)

Temperature

DS1822 (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921 (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3) EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826 (3)

Humidity

DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)

Voltage

DS2450 (3)

Resistance

DS2890 (3)

Multifunction (current, voltage, temperature)

DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760 (3) DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3)

Counter

DS2423 (3)

LCD Screen

LCD (3) DS2408 (3)

Crypto

DS1977 (3)

Pressure

DS2406 (3) TAI8570 EDS0066 (3) EDS0068 (3)

Moisture

EEEF (3) DS2438 (3)

AVAILABILITY

http://www.owfs.org

AUTHOR

Paul Alfille ([email protected])